Instructions on programming the RM5 Electronic Coin Mechanism
The following instructions will assist you in the self-programming of the
RM5 Electronic Coin Mechanism:
- Power down the electrical source of your vending machine.
- Switch "on" the six (6) dip switches located on the side of the RM5 coin
mechanism.
- Power up the electrical source of your vending machine which supplies
the DC voltage. ( +12 or +24 volts DC to the RM5.)
- Insert the 1st coin value "twice" [2 coins]
- Turn off the dip switches 2 thru 6 of the 6 dip switch row.
- Insert the 1st coin value with 15 different coins of the same value a
total of 15 times until the solenoid "clicks".
- With the input electrical power "on"...turn "off" switch #1 of the 1 - 6
switches.
- Switch "off" the input +12 or +24 volts and leave electrical input power
"switched off" a minimum of 5 seconds.
- Power up the input of +12 or +24 volts for 5 seconds.
- Switch "on" all 6 of the switches 1 - 6......then switch power
"off" and then "on".
- Insert the 2nd coin value with two (2) coins or the same coin "twice".
- Switch "off" switches 1, 3 - 6.
- Insert the 2nd set of 15 coins so that a minimum of 15 coins or more are
inserted of the same value until the solenoid "clicks".
- Keep the RM5 powered up with +12 or +24 volts and switch "off" switch #2
of the 1 - 6 dip switches.
- Switch "off" the +12 or +24 volts DC input to the RM5, count to 5
seconds and switch electrical power "on".
- Repeat the above steps for the remaining 4 coins.
- If you have problems....contact our technical services e-mail address;
support@vendapin.com .